BAYD85 Series Explosion-proof Emergency Exit Light Fittings
2019/07/22

◆ Explosion Protection to 

EN, IEC

◆ Can be used in

Zone 1,2,21,22

Class I,Zone 1,2

Class I,Division 1,Groups C, D

◆ Lighting both in normal condition and emergency condition; When power supply is cut off, the emergency device starts to work; with overcharge, overdischarge protection and short circuit protection. 

◆ Designed with test button and sleep button. The test button is for testing. Press the button, lamp shall automatically enter into emergency status. The sleep button is to stop the lamp source output, press this button, the lamp turned off, re-press the button, lamp on and return to work. 

◆ Ultra-bright LED lamp, low power consumption and long service life up to 50,000 hours; energy saving and environmental protection. 

◆ Enclosure in Copper-free Aluminium Alloy, powder coated

surface, yellow (RAL 1021). 

◆Toughened glass sheet resistant to temperature changes.


  • Global (IECEx)IECEx CQM 16.0032X
    Gas and dustEx d IIB T6 Gb, Ex tb IIIC T80℃ Db IP66
    Europe (ATEX)EPT 16 ATEX 2558X
    Gas and dust

    II 2 G Ex d IIB T6 Gb

    II 2 D Ex tb IIIC T80℃ Db IP66

    CertificatesIECEx; ATEX; CU-TR
    Conformity to standardsEN; IEC 
    Degree of protectionIP66


  • Enclosure

    Copper-free Aluminium Alloy, powder coated surface, yellow

    (RAL1021)

    Exposed fastenerStainless steel
    Rated voltage100~300V AC 50/60Hz
    LampLED lamp (working voltage DC 3.6V)
    Power consumption4W
    Emergency time180min
    Rated capacity800mAh
    Charging time24h
    Earthing protectionM5 (internal & external earth bolts)
    Degree of protectionIP66, IP67 (optional)
    Ambient temperature-20℃~+55℃
    Terminal3 x 1.5~2.5mm2 (L+N+PE)
    Cable entries2 x M25 x 1.5 plugs
    Cable glandDQM-II (Ex d) or DQM-III (Ex d) is recommended.
    Weight5.15kg


  • BAYD85 Series Explosion-proof Emergency Exit Light Fittings 

    (Download here:BAYD85 Series Explosion-proof Emergency Exit Light Fittings.pdf


    Global (IECEx): IECEx CQM 16.0032X  

    (Download here:IECEx CQM 16.0032X  Issue No.0 pdf


    Contact us for more information:

    Address : No. 555, Baoqian Road, Jiading District, Shanghai, China

    Zip Code: 201808

    Tel: +86 21 39977076 /+86 21 39977076 

    Fax: +86 21 39977077

    E-mail: gmb@warom.com



Give us a message